# Wire Distance from Controller to Solenoids

Below is a chart indicating the maximum wire run between the controller and the solenoids.

If you are using the same size wire for all your connections

| ## **Wire Sizing (Feet)** |  |  |  |  |  |  |  |
| --- | --- | --- | --- | --- | --- | --- | --- |
|  | **Terminal (Station/Hot/Valve) Wire (colored)** |  |  |  |  |  |  |
| **Common (White)** | **18** | **16** | **14** | **12** | **10** | **8** | **6** |
| **18** | 850 | 1040 | 1210 | 1350 | 1460 | 1540 | 1590 |
| **16** | 1040 | 1340 | 1650 | 1920 | 2150 | 2330 | 2440 |
| **14** | 1210 | 1650 | 2150 | 2630 | 3080 | 3450 | 3700 |
| **12** | 1350 | 1920 | 2630 | 3390 | 4170 | 4880 | 5400 |
| **10** | 1460 | 2150 | 3080 | 4170 | 5400 | 6670 | 7650 |
| **8** | 1540 | 2330 | 3450 | 4880 | 6670 | 8700 | 10530 |
| **6** | 1590 | 2440 | 3700 | 54000 | 7690 | 10530 | 13330 |

**Notes:**
 Maximum one-way distance in feet between controller and heavy-duty solenoid: 24 VAC, 350 mA inrush current, 190 mA holding current, 60 Hz; 370 mA inrush current, 210 mA holding current, 50 Hz

 

| ## **Wire Sizing (Metric)** |  |  |  |  |  |  |
| --- | --- | --- | --- | --- | --- | --- |
|  | **Terminal (Station/Hot/Valve) Wire (colored)** |  |  |  |  |  |
| **Common (White)** | **0.5** | **1** | **1.5** | **2.5** | **4** | **6** |
| **0.5** | 140 | 190 | 210 | 235 | 250 | 260 |
| **1.0** | 190 | 290 | 335 | 415 | 465 | 495 |
| **1.5** | 208 | 335 | 397 | 515 | 595 | 647 |
| **2.5** | 235 | 415 | 515 | 730 | 900 | 1030 |
| **4.0** | 250 | 465 | 595 | 900 | 1175 | 1405 |
| **6.0** | 260 | 495 | 647 | 1030 | 1405 | 1745 |

**Notes:**
 Maximum one-way distance in meters between controller and Heavy-duty solenoid: 24 VAC,
 350 mA inrush current, 190 mA holding current, 60 Hz; 370 mA inrush current, 210 mA holding current, 50 Hz