View Categories

Two-wire

6 articles

Guidelines on Earth Grounding for Irrigation Systems

Last Updated: June 11, 2024

Installers are obligated to establish a connection to earth ground for all electronic irrigation equipment in compliance with Article 250 of the National Electrical Code (NEC). The grounding configuration should include, at minimum, the components described in the following guidelines. Selection of Grounding Electrodes Installers must use grounding electrodes that are either UL-listed or meet...

Two-wire Communication

Last Updated: July 17, 2023

Two-wire is a communication methodology between an irrigation controller and solenoids in the field. Traditional Wiring In traditional “multi-wire” communication, an independent wire is installed between the controller and each individual solenoid. A second or “common wire” is connected to each solenoid and closes this electrical circuit. When sending an “On” command to a specific...

Two-wire layouts

Last Updated: March 10, 2023

There is no limit to the layouts you can create with Two-wire systems. We’ll cover the most common styles used and their benefits. Fish Bone / Star / Tree This is one of the most popular and common layouts. These can be identified by having the main leg exiting the controller and branch lines coming...

Two-wire leg connections and rules

Last Updated: January 20, 2023

The output of the HSC wire paths is 24VAC, 50/60 Hz. Voltage is only present on the legs when stations are active. There is no polarity on the Hydro-Rain decoder system. Use direct burial-rated irrigation wire. The size of the wire determines the effective distance of the two-wire path. See the wiring table for distance...

Understanding 2-Wire Decoder Systems

Last Updated: January 19, 2023

Overview Imagine fifty people who have to get to the same place, each driving their own car. This scene represents the expense of the wire and labor for a conventional installation, with a separate wire running to each valve. Now, imagine if they could all take a bus. The bus makes a stop near each...

Waterproof Wire Connectors Installation

Last Updated: July 17, 2023

INSTALLATION INSTRUCTIONS: Important! Turn off power before installing or removing the connector. Product to be used in accordance with location and national codes. Strip wires. Strip 1/2″ for 18-22 gauge wires; 3/8″ for 12-16 gauge wires. Straighten any frayed strands or conductors. Placed stripped wires together with ends of insulation even. Twist connector onto wires...